Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

4YMD

CL-K1 trimer bound to man(alpha1-2)man

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-01-18
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.92
Spacegroup nameP 1 21 1
Unit cell lengths71.850, 106.650, 78.390
Unit cell angles90.00, 92.17, 90.00
Refinement procedure
Resolution44.080 - 2.870
R-factor0.2157
Rwork0.213
R-free0.26400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4yli
RMSD bond length0.004
RMSD bond angle0.853
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.0802.973
High resolution limit [Å]2.8702.870
Rmerge0.0520.537
Number of reflections24670
<I/σ(I)>11.21.8
Completeness [%]91.093.57
Redundancy2.92.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293100 mM HEPES, 10% v/v ethanol and 4 mM calcium chloride

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon