4YLS
Tubulin Glutamylase
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-12-10 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9774 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 79.126, 122.324, 129.445 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.360 - 2.600 |
R-factor | 0.212 |
Rwork | 0.210 |
R-free | 0.24600 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.591 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHENIX |
Refinement software | PHENIX |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.640 |
High resolution limit [Å] | 2.600 | 7.050 | 2.600 |
Rmerge | 0.144 | 0.091 | 0.528 |
Rmeas | 0.152 | 0.097 | 0.555 |
Rpim | 0.046 | 0.032 | 0.162 |
Total number of observations | 193516 | ||
Number of reflections | 19228 | ||
<I/σ(I)> | 11.5 | ||
Completeness [%] | 97.8 | 99.6 | 84.6 |
Redundancy | 10.1 | 9.4 | 9.7 |
CC(1/2) | 0.983 | 0.897 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 279 | PEG 8000, magnesium acetate |