4YLI
CL-K1 trimer
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-03-15 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.92 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 72.990, 107.590, 77.820 |
Unit cell angles | 90.00, 91.49, 90.00 |
Refinement procedure
Resolution | 48.208 - 2.450 |
R-factor | 0.1887 |
Rwork | 0.187 |
R-free | 0.22120 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1b08 |
RMSD bond length | 0.003 |
RMSD bond angle | 0.616 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.210 | 2.538 |
High resolution limit [Å] | 2.450 | 2.450 |
Rmerge | 0.054 | 0.476 |
Number of reflections | 42224 | |
<I/σ(I)> | 10.09 | 2.03 |
Completeness [%] | 95.5 | 87.15 |
Redundancy | 3.3 | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 100 mM HEPES pH 7.0 10% v/v ethanol and 4 mM calcium chloride |