Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4YKU

Heat Shock Protein 90 Bound to CS311

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2012-06-13
DetectorRAYONIX MX-300
Wavelength(s)0.97852
Spacegroup nameI 2 2 2
Unit cell lengths65.067, 88.599, 100.043
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.390 - 1.700
R-factor0.1769
Rwork0.176
R-free0.19550
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)In-house APO Structure
RMSD bond length0.010
RMSD bond angle0.960
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Refinement softwareBUSTER-TNT (BUSTER 2.11.1)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0001.730
High resolution limit [Å]1.7004.6101.700
Rmerge0.0630.0450.383
Total number of observations226668
Number of reflections31714
<I/σ(I)>13.1
Completeness [%]99.997.8100
Redundancy7.16.67.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP827726% Peg 4000, 0.2 M MgCl2, 0.1 M Tris pH 8.0, Cryo Conditions: 35% Peg 4000, 10% glycerol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon