4YKH
Thirty minutes iron loaded human H ferritin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-07-05 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.92 |
Spacegroup name | F 4 3 2 |
Unit cell lengths | 184.050, 184.050, 184.050 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 28.070 - 1.520 |
R-factor | 0.16583 |
Rwork | 0.165 |
R-free | 0.18713 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3ajo |
RMSD bond length | 0.006 |
RMSD bond angle | 1.007 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.100 | 1.600 |
High resolution limit [Å] | 1.520 | 1.520 |
Rmerge | 0.077 | 0.410 |
Number of reflections | 41531 | |
<I/σ(I)> | 25.8 | 7 |
Completeness [%] | 100.0 | 100 |
Redundancy | 19.5 | 17.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 9 | 281 | 2.0 M magnesium chloride, 0.1 M Bicine pH 9.0 |