4X3A
gallus interleukin-1 beta mutant - R140A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL13B1 |
Synchrotron site | NSRRC |
Beamline | BL13B1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-11-04 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 35.773, 37.963, 104.319 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 26.090 - 1.750 |
R-factor | 0.22279 |
Rwork | 0.220 |
R-free | 0.26824 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2wry |
RMSD bond length | 0.017 |
RMSD bond angle | 1.883 |
Data scaling software | DENZO (HKL-2000) |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 26.090 |
High resolution limit [Å] | 1.750 |
Number of reflections | 15110 |
<I/σ(I)> | 32.5 |
Completeness [%] | 98.1 |
Redundancy | 8.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 1.15 M (NH4)2SO4, 0.1 M Tris, 0.2 M LiSO4 |