4X2J
Selection of fragments for kinase inhibitor design: decoration is key
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2007-12-13 |
| Detector | PSI PILATUS 6M |
| Wavelength(s) | 1.00000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 42.310, 77.510, 90.200 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 22.540 - 1.690 |
| R-factor | 0.1668 |
| Rwork | 0.153 |
| R-free | 0.18420 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.020 |
| Data reduction software | XDS |
| Refinement software | BUSTER (2.11.4) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 45.080 |
| High resolution limit [Å] | 1.690 |
| Number of reflections | 33372 |
| <I/σ(I)> | 21.4 |
| Completeness [%] | 99.0 |
| Redundancy | 7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M Tris-HCl, 240 mM Li2SO4, 24% PEG 4000, pH 7.5 |