Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4WWU

Structure of Mex67:Mtr2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2014-01-07
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.9200
Spacegroup nameP 1 21 1
Unit cell lengths100.610, 76.720, 199.120
Unit cell angles90.00, 94.09, 90.00
Refinement procedure
Resolution49.653 - 3.301
R-factor0.2311
Rwork0.228
R-free0.28430
RMSD bond length0.004
RMSD bond angle0.813
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 Overall
Low resolution limit [Å]49.700
High resolution limit [Å]3.300
Number of reflections44836
<I/σ(I)>5.1
Completeness [%]97.4
Redundancy3.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP291See publication for details. Precipitant was 10 % PEG 8000, 0.01 M zinc acetate, 0.1 M Tris-HCl pH 8.0.

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon