4WU7
HLA-A24 in complex with HIV-1 Nef134-8(2F)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL41XU |
Synchrotron site | SPring-8 |
Beamline | BL41XU |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-10-08 |
Detector | RAYONIX MX225HE |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 67.714, 87.020, 152.227 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.297 |
R-factor | 0.2248 |
Rwork | 0.222 |
R-free | 0.28700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3vxn |
RMSD bond length | 0.007 |
RMSD bond angle | 1.114 |
Data reduction software | SCALEPACK |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.297 |
Number of reflections | 37537 |
<I/σ(I)> | 14.06 |
Completeness [%] | 93.0 |
Redundancy | 4.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 200mM sodium nitrate, 20%PEG3350 |