Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4U5L

IMPORTIN-ALPHA MINOR NLS SITE INHIBITOR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]100
Detector technologyPIXEL
Collection date2012-09-20
DetectorPSI PILATUS 6M
Wavelength(s)0.9192
Spacegroup nameP 21 21 21
Unit cell lengths78.896, 90.604, 100.409
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.833 - 2.530
R-factor0.1836
Rwork0.181
R-free0.22210
RMSD bond length0.009
RMSD bond angle1.217
Refinement softwarePHENIX ((phenix.refine: dev_1702))
Data quality characteristics
 Overall
Low resolution limit [Å]19.833
High resolution limit [Å]2.530
Number of reflections24615
<I/σ(I)>7.9
Completeness [%]99.7
Redundancy10.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP291see manuscript

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon