4TXS
An Ligand-observed Mass Spectrometry-based Approach Integrated into the Fragment Based Lead Discovery Pipeline
Experimental procedure
| Experimental method | LAUE |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2012-05-23 |
| Detector | RIGAKU RAXIS HTC |
| Wavelength(s) | 1.5415 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 102.177, 102.077, 251.875 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.690 - 2.780 |
| R-factor | 0.22328 |
| Rwork | 0.220 |
| R-free | 0.29365 |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.544 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.780 |
| Number of reflections | 66889 |
| <I/σ(I)> | 25.8 |
| Completeness [%] | 95.0 |
| Redundancy | 6.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | PEG4000, Dithiothreitol, 2-(N-morpholino)ethanesulfonic acid, Glycerin |