4TQL

Computationally designed three helix bundle

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]100
Detector technologyCCD
Collection date2012-11-15
DetectorADSC QUANTUM 315
Wavelength(s)0.999
Spacegroup nameP 1
Unit cell lengths24.877, 41.547, 133.202
Unit cell angles98.94, 92.25, 90.06
Refinement procedure
Resolution43.826 - 2.800
Rwork0.264
R-free0.31000
RMSD bond length0.013
RMSD bond angle1.569
Refinement softwarePHENIX ((phenix.refine: 1.8.2_1309))
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.800
Number of reflections12173
<I/σ(I)>14.3
Completeness [%]94.2
Redundancy1.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82960.1 M Tris HCl, 30% Jeffamine M-600

219869