4RP9
Bacterial vitamin C transporter UlaA/SgaT in C2 form
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-03-06 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.02245 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 113.663, 85.812, 83.236 |
| Unit cell angles | 90.00, 127.97, 90.00 |
Refinement procedure
| Resolution | 32.791 - 1.651 |
| R-factor | 0.1358 |
| Rwork | 0.134 |
| R-free | 0.17400 |
| Structure solution method | MIR |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.386 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SOLVE |
| Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.650 |
| Number of reflections | 71471 |
| Completeness [%] | 94.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 291 | 0.1M MES pH 6.5, 0.1M NaCl, 30%(v/v) polyethyleneglycol(PEG)400, VAPOR DIFFUSION, HANGING DROP, temperature 291K |