4RP8
Bacterial vitamin C transporter UlaA/SgaT in P21 form
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-03-06 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.9794 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 83.781, 85.561, 88.954 |
| Unit cell angles | 90.00, 96.73, 90.00 |
Refinement procedure
| Resolution | 38.503 - 2.359 |
| R-factor | 0.1989 |
| Rwork | 0.197 |
| R-free | 0.23880 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4rp9 |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.945 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.350 |
| Number of reflections | 49177 |
| Completeness [%] | 96.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 291 | 0.1M MES pH 6.5, 0.1M NaCl, 30%(v/v) polyethyleneglycol(PEG)400, VAPOR DIFFUSION, HANGING DROP, temperature 291K |