4R98
Chimera of the N-terminal domain of E. coli FeoB
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Synchrotron site | APS |
Beamline | 23-ID-B |
Detector technology | IMAGE PLATE |
Collection date | 2010-09 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54 |
Spacegroup name | P 41 |
Unit cell lengths | 48.452, 48.452, 233.393 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.750 - 2.220 |
R-factor | 0.25089 |
Rwork | 0.249 |
R-free | 0.28101 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.884 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.280 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.044 | 0.224 |
Number of reflections | 26345 | |
Completeness [%] | 97.1 | 73.6 |
Redundancy | 6.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 22 % PEG 3350, 0.1 M Bis Tris Propane pH 6.5 and 0.2 M Sodium formate, VAPOR DIFFUSION, HANGING DROP | |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 22 % PEG 3350, 0.1 M Bis Tris Propane pH 6.5 and 0.2 M Sodium formate, VAPOR DIFFUSION, HANGING DROP |