4QMI
The XMAP215 family drives microtubule polymerization using a structurally diverse TOG array
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-BM |
Synchrotron site | APS |
Beamline | 22-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-08-07 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.00000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.418, 74.293, 93.684 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.670 - 1.900 |
R-factor | 0.1767 |
Rwork | 0.174 |
R-free | 0.21530 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.068 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((phenix.refine: 1.7.3_928)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.082 | 0.428 |
<I/σ(I)> | 22.9 | 4.7 |
Completeness [%] | 100.0 | 100 |
Redundancy | 7.1 | 6.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293.15 | 10 mg/mL protein was added to an equal volume of a mother liquor containing 28% PEG 4000, 100 mM Tris pH 7.5, and 125 mM MgCl2, VAPOR DIFFUSION, HANGING DROP, temperature 293.15K |