Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH3R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2011-04-02 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.356, 41.463, 72.461 |
Unit cell angles | 90.00, 104.39, 90.00 |
Refinement procedure
Resolution | 35.699 - 1.469 |
R-factor | 0.1247 |
Rwork | 0.123 |
R-free | 0.15810 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.230 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHENIX |
Refinement software | PHENIX ((phenix.refine: 1.8.3_1479)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.510 |
High resolution limit [Å] | 1.470 | 1.470 |
Number of reflections | 38496 | |
Completeness [%] | 92.2 | 86 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 1.3 M Sodium Citrate, 50 mM Tris pH 8, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K |