4Q4H
TM287/288 in its apo state
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 90 |
Detector technology | CCD |
Collection date | 2010-12-09 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 214.640, 84.010, 114.110 |
Unit cell angles | 90.00, 93.27, 90.00 |
Refinement procedure
Resolution | 29.512 - 2.527 |
R-factor | 0.2395 |
Rwork | 0.237 |
R-free | 0.29040 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.922 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8_1069)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 29.512 |
High resolution limit [Å] | 2.527 |
Number of reflections | 59480 |
Completeness [%] | 87.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293.15 | 26 % (w/v) polyethylene glycol (PEG) 400, 50 mM Na-cacodylate, 50 mM CaCl2, 2.5 mM ADP and 3 mM MgCl2, pH 5.5, VAPOR DIFFUSION, SITTING DROP, temperature 293.15K |