4PTH
Ensemble model for Escherichia coli dihydrofolate reductase at 100K
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL11-1 |
Synchrotron site | SSRL |
Beamline | BL11-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-04-25 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 33.960, 44.823, 98.254 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.000 - 0.850 |
R-factor | 0.1268 |
Rwork | 0.126 |
R-free | 0.14450 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1rx2 |
RMSD bond length | 0.018 |
RMSD bond angle | 1.555 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHELX |
Refinement software | PHENIX (1.8.4-1496) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.000 | 0.880 |
High resolution limit [Å] | 0.850 | 0.850 |
Rmerge | 0.049 | 0.550 |
Number of reflections | 130200 | |
<I/σ(I)> | 36.3 | 2.3 |
Completeness [%] | 98.2 | 97.2 |
Redundancy | 5.5 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 277 | 17% PEG 400, 20 mM imidazole pH 7.0, 125 mM MnCl2, VAPOR DIFFUSION, HANGING DROP, temperature 277K |