4PPT
Engineered Dual Specific VHH Antibody in Complex with a Nickel (II) Ion
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-BM |
| Synchrotron site | APS |
| Beamline | 22-BM |
| Detector technology | CCD |
| Collection date | 2010-07-13 |
| Detector | MAR CCD 165 mm |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 53.824, 61.926, 66.319 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.640 - 1.500 |
| R-factor | 0.194 |
| Rwork | 0.192 |
| R-free | 0.22400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.015 |
| RMSD bond angle | 1.570 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.500 |
| Number of reflections | 110728 |
| Completeness [%] | 99.8 |
| Redundancy | 11.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298.15 | 1.8 M Ammonium Citrate Tribasic, 0.2 M Ammonium Acetate, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 298.15K |