4PLJ
Hepatitis E Virus E2s domain (Genotype IV) in complex with a neutralizing antibody 8G12
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-12-10 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 56.775, 89.459, 137.636 |
Unit cell angles | 90.00, 95.90, 90.00 |
Refinement procedure
Resolution | 29.137 - 2.300 |
R-factor | 0.1888 |
Rwork | 0.187 |
R-free | 0.24220 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.158 |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 30.000 |
High resolution limit [Å] | 2.300 |
Number of reflections | 61168 |
<I/σ(I)> | 14.3 |
Completeness [%] | 99.8 |
Redundancy | 5.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 294 | 14% PEG 1500 |