Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4P7G

Rat apo-COMT, phosphate bound

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyCCD
Collection date2009-09-12
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1
Spacegroup nameP 32 2 1
Unit cell lengths71.600, 71.600, 393.438
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution48.700 - 2.580
R-factor0.2114
Rwork0.210
R-free0.24740
RMSD bond length0.010
RMSD bond angle1.110
Refinement softwareBUSTER (2.11.4)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.7002.670
High resolution limit [Å]2.5802.580
Rmerge0.2350.645
Number of reflections36241
<I/σ(I)>16.13471.5359
Completeness [%]95.786.5
Redundancy4.92.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293see manuscript

219869