42F3 TCR pCPA12/H-2Ld complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]100
Detector technologyPIXEL
Collection date2011-02-10
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.0332
Spacegroup nameP 61 2 2
Unit cell lengths101.570, 101.570, 327.130
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution59.895 - 3.059
R-factor0.1956
Rwork0.194
R-free0.22700
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle0.869
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.2_1309))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]109.1103.220
High resolution limit [Å]3.0603.060
Number of reflections19619
Completeness [%]98.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529316% PEG 3350, 100mM TRIS, pH 7.5 and 200mM magnesium nitrate, VAPOR DIFFUSION, SITTING DROP, temperature 293K

219869