Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-02-08 |
| Detector | MARMOSAIC 300 mm CCD |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 55.035, 105.795, 171.503 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.958 - 2.605 |
| R-factor | 0.1738 |
| Rwork | 0.170 |
| R-free | 0.24270 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.301 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (dev_1458) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 2.690 |
| High resolution limit [Å] | 2.600 | 5.600 | 2.600 |
| Rmerge | 0.140 | 0.097 | 0.416 |
| Number of reflections | 28364 | ||
| <I/σ(I)> | 11 | ||
| Completeness [%] | 90.1 | 99.9 | 64.1 |
| Redundancy | 7.3 | 7.9 | 5.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 25% PEG 4K, 10% glycerol, 0.1M Tris-HCl, pH 8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |