frog M ferritin iron-loaded under anaerobic environment

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2013-04-13
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.976, 1.722, 1.758
Spacegroup nameF 4 3 2
Unit cell lengths183.830, 183.830, 183.830
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.110 - 1.480
R-factor0.17548
Rwork0.174
R-free0.19504
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ka3
RMSD bond length0.005
RMSD bond angle0.999
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.96045.9601.560
High resolution limit [Å]1.4804.6801.480
Rmerge0.0860.0630.420
Number of reflections55514
<I/σ(I)>15.429.74.7
Completeness [%]100.099.8100
Redundancy9.78.79.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP92771.6-2M magnesium chloride, 0.1M bicine, pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K

219869