Radiation damage study of Cu T6-insulin - 0.30 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsCu FINE FOCUS
Detector technologyCCD
Collection date2013-06-14
DetectorAGILENT ATLAS CCD
Wavelength(s)1.5418
Spacegroup nameH 3
Unit cell lengths80.650, 80.650, 33.313
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution16.746 - 1.900
R-factor0.1711
Rwork0.169
R-free0.21990
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.034
Data reduction softwareCrysalisPro
Data scaling softwareCrysalisPro
Phasing softwareMOLREP
Refinement softwarePHENIX ((phenix.refine: 1.8.1_1168))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]16.7501.970
High resolution limit [Å]1.9001.900
Number of reflections6340
Completeness [%]99.699.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.12980.05M sodium citrate, 15%(v/v) acetone, 7.5mM copper(II)acetate, pH 7.1, VAPOR DIFFUSION, HANGING DROP, temperature 298K