Two minutes iron loaded frog M ferritin

Experimental procedure
Experimental methodMAD
Source typeSYNCHROTRON
Source detailsELETTRA BEAMLINE 5.2R
Synchrotron siteELETTRA
Beamline5.2R
Temperature [K]100
Detector technologyPIXEL
Collection date2012-05-03
DetectorDECTRIS PILATUS 2M-F
Wavelength(s)0.99999, 1.72202, 1.75866
Spacegroup nameF 4 3 2
Unit cell lengths184.548, 184.548, 184.548
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.140 - 1.200
R-factor0.13614
Rwork0.136
R-free0.14494
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ka3
RMSD bond length0.005
RMSD bond angle0.998
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.14046.1401.260
High resolution limit [Å]1.2003.7901.200
Rmerge0.0640.0340.409
Number of reflections83387
<I/σ(I)>16.3444.7
Completeness [%]99.699.199
Redundancy9.29.38.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP92771.6-2M magnesium chloride, 0.1M bicine , pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K

246031