Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4LMX

Light harvesting complex PE555 from the cryptophyte Hemiselmis andersenii CCMP644

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2010-06-12
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.97934
Spacegroup nameP 1 21 1
Unit cell lengths66.073, 76.741, 142.593
Unit cell angles90.00, 92.86, 90.00
Refinement procedure
Resolution18.636 - 1.800
R-factor0.1609
Rwork0.158
R-free0.21390
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1qgw
RMSD bond length0.006
RMSD bond angle1.076
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7.2_867))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]142.4161.900
High resolution limit [Å]1.8001.800
Rmerge0.0790.488
Number of reflections131573
<I/σ(I)>112.9
Completeness [%]99.697.7
Redundancy2.62.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529525% PEG10000, 0.1 M HEPES, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 295K

219869