Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4L75

Ca2+-bound D184N mutant MthK RCK domain at 2.4 Angstrom

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X25
Synchrotron siteNSLS
BeamlineX25
Temperature [K]100
Detector technologyPIXEL
Collection date2011-10-05
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.1
Spacegroup nameP 65 2 2
Unit cell lengths119.228, 119.228, 353.958
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.593 - 2.393
R-factor0.1975
Rwork0.196
R-free0.24510
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2aef
RMSD bond length0.007
RMSD bond angle1.016
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.2_1309)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]45.00045.0002.490
High resolution limit [Å]2.3935.1702.393
Rmerge0.0840.044
Number of reflections59525
<I/σ(I)>6.5
Completeness [%]99.899100
Redundancy16.617.610.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.82957% PEG4000, 1 M ammonium formate, 0.1 M sodium acetate, pH 4.8, 0.3 M calcium chloride, VAPOR DIFFUSION, HANGING DROP, temperature 295K

220113

PDB entries from 2024-05-22