4KPX
Hin GlmU bound to WG766
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E+ SUPERBRIGHT |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-05-25 |
| Detector | RIGAKU SATURN 944+ |
| Wavelength(s) | 1.54 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 108.190, 108.190, 325.870 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 31.040 - 2.210 |
| R-factor | 0.1866 |
| Rwork | 0.185 |
| R-free | 0.22650 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.170 |
| Data reduction software | XDS |
| Data scaling software | SCALA |
| Phasing software | AMoRE |
| Refinement software | BUSTER (2.11.5) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.320 |
| High resolution limit [Å] | 2.210 | 2.210 |
| Number of reflections | 36717 | |
| Completeness [%] | 98.6 | 100 |
| Redundancy | 10.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.9 | 293 | 2.0 M ammonium sulfate, 2% PEG400, 0.1 M MES, pH 5.9, VAPOR DIFFUSION, HANGING DROP, temperature 293K |