4KJJ
Cryogenic WT DHFR
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.3.1 |
Synchrotron site | ALS |
Beamline | 8.3.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-10-25 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.115869 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 34.040, 44.820, 98.200 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.774 - 1.150 |
R-factor | 0.1375 |
Rwork | 0.137 |
R-free | 0.15650 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.014 |
RMSD bond angle | 1.886 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX (dev_1388) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.190 |
High resolution limit [Å] | 1.150 | 1.150 |
Number of reflections | 51212 | |
Completeness [%] | 94.4 | 64.25 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 100mM HEPES pH 7.5, 21% PEG8000, 200mM MgCl2, VAPOR DIFFUSION, HANGING DROP, temperature 293K |