Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4K8H

OYE1-W116V complexed with (R)-carvone

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X6A
Synchrotron siteNSLS
BeamlineX6A
Temperature [K]100
Detector technologyCCD
Collection date2011-08-15
DetectorADSC QUANTUM 270
Wavelength(s)0.88560
Spacegroup nameP 43 21 2
Unit cell lengths141.443, 141.443, 42.851
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.477 - 1.550
R-factor0.1282
Rwork0.124
R-free0.16200
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.205
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.8.2_1309))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.4861.610
High resolution limit [Å]1.5501.550
Rmerge0.0860.676
Number of reflections63649
<I/σ(I)>36.73.8
Completeness [%]99.999
Redundancy12.212.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.32770.2M MgCl2, 0.1M HEPES, 30-40% PEG400, pH 8.3, VAPOR DIFFUSION, HANGING DROP, temperature 277K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon