4K36
His6 tagged anSMEcpe with bound AdoMet
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2011-02-28 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.9794 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 46.561, 92.617, 92.348 |
| Unit cell angles | 90.00, 94.00, 90.00 |
Refinement procedure
| Resolution | 36.997 - 1.619 |
| R-factor | 0.1828 |
| Rwork | 0.182 |
| R-free | 0.19530 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.402 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.8.2_1309) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.600 |
| Number of reflections | 97728 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 298 | 9% PEG 2000, 100 mM MES, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |