4JMI
Sec7 domain of ARNO, an exchange factor, at 1.5 Angstrom resolution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-2 |
Synchrotron site | ESRF |
Beamline | ID23-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-12-10 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.97628 |
Spacegroup name | P 21 3 |
Unit cell lengths | 89.540, 89.540, 89.540 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.770 - 1.500 |
R-factor | 0.13459 |
Rwork | 0.133 |
R-free | 0.16616 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1pbv |
RMSD bond length | 0.007 |
RMSD bond angle | 1.115 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.770 | 1.580 |
High resolution limit [Å] | 1.500 | 1.500 |
Rmerge | 0.342 | |
Number of reflections | 38574 | |
Completeness [%] | 100.0 | 100 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 298 | 0.1M MgSO4, Peg 5000 MME 18%, 0.1M Mes pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K |