Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4JMI

Sec7 domain of ARNO, an exchange factor, at 1.5 Angstrom resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-2
Synchrotron siteESRF
BeamlineID23-2
Temperature [K]100
Detector technologyCCD
Collection date2012-12-10
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.97628
Spacegroup nameP 21 3
Unit cell lengths89.540, 89.540, 89.540
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.770 - 1.500
R-factor0.13459
Rwork0.133
R-free0.16616
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1pbv
RMSD bond length0.007
RMSD bond angle1.115
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.7.0032)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.7701.580
High resolution limit [Å]1.5001.500
Rmerge0.342
Number of reflections38574
Completeness [%]100.0100
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.52980.1M MgSO4, Peg 5000 MME 18%, 0.1M Mes pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon