Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 4A |
| Synchrotron site | PAL/PLS |
| Beamline | 4A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-05-26 |
| Detector | ADSC QUANTUM 210 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 85.722, 124.357, 146.164 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.720 - 2.290 |
| R-factor | 0.184 |
| Rwork | 0.180 |
| R-free | 0.24700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3e6g |
| RMSD bond length | 0.022 |
| RMSD bond angle | 1.992 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASES |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.350 |
| High resolution limit [Å] | 2.290 | 2.290 |
| Number of reflections | 35240 | |
| Completeness [%] | 99.2 | 92 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.2 | 293 | 23% PEG 3350, 0.2M LITHIUM SULFATE, 0.1M BIS-TRIS, 0.2M SODIUM THIOCYANATE, PH 5.2, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293K |