4IUL
MIF4G domain of DAP5
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CHESS BEAMLINE A1 |
| Synchrotron site | CHESS |
| Beamline | A1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-04-30 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 0.9785 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 167.696, 56.696, 74.374 |
| Unit cell angles | 90.00, 112.05, 90.00 |
Refinement procedure
| Resolution | 30.000 - 2.300 |
| R-factor | 0.224 |
| Rwork | 0.221 |
| R-free | 0.25600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1hu3 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | CCP4 |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Number of reflections | 28017 | |
| Completeness [%] | 99.8 | 87.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | 0.1 M HEPES pH 7.5, 0.2 M ammonium sulfate and 18 20% (w/v) polyethylene glycol 5000 monomethyl ether, VAPOR DIFFUSION, HANGING DROP, temperature 291K |