4ION
Macrolepiota procera ricin B-like lectin (MPL)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-09-10 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 1.0 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 64.443, 64.443, 156.866 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 38.160 - 1.600 |
R-factor | 0.1882 |
Rwork | 0.186 |
R-free | 0.22310 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | partial model obtained by iodine SAD |
RMSD bond length | 0.014 |
RMSD bond angle | 1.330 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | SHELX |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.160 | 1.700 |
High resolution limit [Å] | 1.600 | 1.600 |
Rmerge | 0.788 | |
<I/σ(I)> | 1.91 | |
Completeness [%] | 99.7 | 98.6 |
Redundancy | 8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.04 M KH2phosphate, 12 %(w/v) PEG 8000, 20 %(v/v) Glycerol, VAPOR DIFFUSION, SITTING DROP, temperature 293K |