4ICZ
HER2 1221/1222 phosphorylation regulated by PTPN9
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Detector technology | CCD |
| Collection date | 2012-05-06 |
| Detector | RAYONIX MX-225 |
| Wavelength(s) | 0.98 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 73.249, 85.705, 49.781 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 41.173 - 1.900 |
| R-factor | 0.2055 |
| Rwork | 0.203 |
| R-free | 0.24870 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.045 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Refinement software | PHENIX ((phenix.refine: 1.6.2_432)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 80.000 |
| High resolution limit [Å] | 1.900 |
| Number of reflections | 25510 |
| Completeness [%] | 99.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.4 | 293 | 20% PEG-4000, 0.2 M potassium thiocyanate, 10% ethylene glycol, 0.1 M Bis-Tris propane pH 6.4, VAPOR DIFFUSION, HANGING DROP, temperature 293K |