Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4IA7

Diastereotopic and Deuterium Effects in Gemini

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-1
Synchrotron siteESRF
BeamlineID14-1
Temperature [K]100
Detector technologyCCD
Collection date2012-05-01
DetectorADSC QUANTUM 4r
Spacegroup nameP 65 2 2
Unit cell lengths66.178, 66.178, 266.412
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution25.000 - 2.700
R-factor0.21
Rwork0.210
R-free0.25500
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.190
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.0002.800
High resolution limit [Å]2.7002.700
Number of reflections10345
Completeness [%]100.0100
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.5293Bis-Tris 0.1 M, lithium sulfate 1.6 M and magnesium sulfate 50 mM , pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon