4HTW
SIVmac239 capsid N-terminal domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-03-30 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9792 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 24.614, 56.663, 102.566 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.273 - 2.900 |
R-factor | 0.2558 |
Rwork | 0.254 |
R-free | 0.29270 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.950 |
High resolution limit [Å] | 2.900 | 7.860 | 2.900 |
Rmerge | 0.063 | 0.036 | 0.365 |
Number of reflections | 3537 | ||
<I/σ(I)> | 10.4 | ||
Completeness [%] | 99.9 | 100 | 98.8 |
Redundancy | 4.4 | 3.6 | 4.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 292 | 10% PEG 2000 MME, 10mM nickel chloride and 100mM Tris., pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K |