4HR9
Human interleukin 17A
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Detector technology | CCD |
| Collection date | 2011-03-16 |
| Wavelength(s) | 1.0 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 64.350, 85.250, 119.860 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.930 - 2.480 |
| R-factor | 0.2112 |
| Rwork | 0.210 |
| R-free | 0.23300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.260 |
| Refinement software | BUSTER (2.11.1) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 120.000 |
| High resolution limit [Å] | 2.480 |
| Rmerge | 0.046 |
| Number of reflections | 12055 |
| <I/σ(I)> | 26.9 |
| Completeness [%] | 100.0 |
| Redundancy | 6.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |