4HKR
Calcium release-activated calcium (CRAC) channel ORAI
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X25 |
Synchrotron site | NSLS |
Beamline | X25 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-04-22 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.10 |
Spacegroup name | P 21 3 |
Unit cell lengths | 117.910, 117.910, 117.910 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.930 - 3.351 |
R-factor | 0.278 |
Rwork | 0.278 |
R-free | 0.27940 |
Structure solution method | MOLECULAR REPLACEMENT, SAD |
Starting model (for MR) | 4hks |
RMSD bond length | 0.009 |
RMSD bond angle | 1.336 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHARP |
Refinement software | PHENIX ((1.8_1069)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 3.410 |
High resolution limit [Å] | 3.350 | 3.350 |
Number of reflections | 8116 | |
<I/σ(I)> | 59.7 | 1.2 |
Completeness [%] | 100.0 | 100 |
Redundancy | 40.5 | 40.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 290 | 26% PEG 400, 1 M Ammonium Formate, 100 mM MES pH 6.5. The crystal was soaked in: 50 % PEG 400, 1 M Ammonium Formate, 100 mM MES pH 6.5, 50 mM barium chloride, VAPOR DIFFUSION, HANGING DROP, temperature 290K |