Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4H92

Radiation damage study of lysozyme- 0.42 MGy

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]100
Detector technologyCCD
Collection date2011-02-12
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)1.0332
Spacegroup nameP 43 21 2
Unit cell lengths78.761, 78.761, 36.861
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.911 - 1.200
R-factor0.1897
Rwork0.189
R-free0.19930
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6lyz
RMSD bond length0.006
RMSD bond angle1.124
Data reduction softwareHKL-2000
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX (1.7.2_862)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]1.200
Number of reflections36557
<I/σ(I)>43.6
Completeness [%]96.9
Redundancy4.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.82987.5% sodium chloride, 100 mM sodium acetate pH 4.8, 25% ethylene glycol, vapor diffusion, hanging drop, temperature 298K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon