Room temperature X-ray diffraction study of a 6-fold molar excess of a cisplatin/carboplatin mixture binding to HEWL, Dataset 3

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsBRUKER AXS MICROSTAR-H
Temperature [K]300
Detector technologyCCD
Collection date2012-05-25
DetectorAPEX II CCD
Wavelength(s)1.5418
Spacegroup nameP 43 21 2
Unit cell lengths79.863, 79.863, 37.802
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution56.470 - 2.900
R-factor0.17673
Rwork0.174
R-free0.23407
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2w1y
RMSD bond length0.010
RMSD bond angle1.311
Data reduction softwareAPEX
Phasing softwarePHASER (MR)
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.4702.970
High resolution limit [Å]2.9002.900
Rmerge0.3800.627
Number of reflections2816
<I/σ(I)>8.13.5
Completeness [%]99.8100
Redundancy23.225.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
14.727749 mg HEWL (3.2 mM), 3 mg cisplatin (10 mM), 3.7 mg carboplatin (10 mM) in 0.04 M sodium acetate buffer (462.5 uL) + 10% sodium chloride precipitant (462.5 uL) + 1 mM DMSO (75 uL), pH 4.7, BATCH, temperature 277K