Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | MACSCIENCE |
Temperature [K] | 293 |
Detector technology | AREA DETECTOR |
Collection date | 2001-02-09 |
Detector | SIEMENS HI-STAR |
Wavelength(s) | 1.5418 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 65.386, 77.607, 145.411 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 41.200 - 2.200 |
R-factor | 0.1963 |
Rwork | 0.194 |
R-free | 0.23940 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | PDB 3EVH |
RMSD bond length | 0.013 |
RMSD bond angle | 1.369 |
Data reduction software | SAINT |
Data scaling software | SAINT |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 41.200 | 2.280 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 38230 | |
<I/σ(I)> | 13.2 | 2.8 |
Completeness [%] | 99.4 | 97.5 |
Redundancy | 5.6 | 2.86 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 293 | 24%(W/V) PEG4000, 0.3M AMMONIUM ACETATE, 0.1M SODIUM CITRATE, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |