4E5A
The W197A mutant of p38a MAP kinase
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-1 |
| Synchrotron site | ESRF |
| Beamline | ID23-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-06-29 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.976 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 72.493, 75.740, 76.588 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 1.870 |
| R-factor | 0.21112 |
| Rwork | 0.209 |
| R-free | 0.25327 |
| Structure solution method | MIR |
| RMSD bond length | 0.017 |
| RMSD bond angle | 1.565 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.860 |
| Number of reflections | 33999 |
| <I/σ(I)> | 37.6 |
| Completeness [%] | 96.0 |
| Redundancy | 2.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 277 | 3%-17% (w/v) PEG 3350, 0.1M Hepes pH 6.5-7.25, 0.2M KF, VAPOR DIFFUSION, SITTING DROP, temperature 277K |