Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4DRX

GTP-Tubulin in complex with a DARPIN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyCCD
Collection date2011-04-11
DetectorADSC QUANTUM 315r
Spacegroup nameP 1 21 1
Unit cell lengths104.884, 90.596, 117.575
Unit cell angles90.00, 90.02, 90.00
Refinement procedure
Resolution39.190 - 2.220
R-factor0.161
Rwork0.159
R-free0.19400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ryc
RMSD bond length0.010
RMSD bond angle0.804
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7.2_869))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.1902.350
High resolution limit [Å]2.2202.220
Rmerge0.015
Number of reflections104776
<I/σ(I)>12.382.08
Completeness [%]96.095
Redundancy2.98
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17292PEG 6K, 0.05M KCl, 0.01 M MGCL2, 0.2M LiCl, 0.01 M HEPES pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 292K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon