Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

4D4G

Understanding bi-specificity of A-domains

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P14 (MX2)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP14 (MX2)
Temperature [K]100
Detector technologyPIXEL
Collection date2013-08-26
DetectorDECTRIS PILATUS 6M
Spacegroup nameP 21 21 21
Unit cell lengths68.311, 81.807, 89.729
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution60.450 - 2.250
R-factor0.18477
Rwork0.182
R-free0.22982
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1amu
RMSD bond length0.010
RMSD bond angle1.464
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0032)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]89.7002.370
High resolution limit [Å]2.2502.250
Rmerge0.0900.430
Number of reflections24234
<I/σ(I)>15.54
Completeness [%]99.198.4
Redundancy5.55.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1624-30% POLYETHYLENE GLYCOL 3350, 0.1 M MES OR BIS-TRIS PH 5.5 - 6.5

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon