Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4BBJ

Copper-transporting PIB-ATPase in complex with beryllium fluoride representing the E2P state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2011-02-20
DetectorDECTRIS PILATUS 6M
Spacegroup nameC 1 2 1
Unit cell lengths242.010, 71.370, 72.430
Unit cell angles90.00, 100.01, 90.00
Refinement procedure
Resolution48.172 - 2.750
R-factor0.2023
Rwork0.199
R-free0.24680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3rfu
RMSD bond length0.010
RMSD bond angle1.234
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.2002.800
High resolution limit [Å]2.7002.700
Rmerge0.1200.970
Number of reflections32589
<I/σ(I)>21.272.94
Completeness [%]96.694.1
Redundancy77.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
16.8pH 6.8

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon