4ATI
MITF:M-box complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-02-16 |
Detector | ADSC QUANTUM 315r |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 118.990, 104.260, 44.900 |
Unit cell angles | 90.00, 112.15, 90.00 |
Refinement procedure
Resolution | 37.869 - 2.600 |
R-factor | 0.2302 |
Rwork | 0.227 |
R-free | 0.27370 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ath |
RMSD bond length | 0.010 |
RMSD bond angle | 1.361 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 55.000 | 2.740 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.050 | 0.390 |
Number of reflections | 15081 | |
<I/σ(I)> | 15.6 | 3.1 |
Completeness [%] | 96.6 | 96.6 |
Redundancy | 3.5 | 3.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |